Entrée Température

Isolateur de résistance Série 9180
Isolateur de résistance Série 9180
  • Weltweit einziges zweikanaliges Gerät auf dem Markt
    • wenig Platzbedarf, nur 8,8 mm pro Kanal
  • Für 2-, 3- und 4-Leiterschaltung
  • Widerstandsbereich von 18 ... 391 Ω oder 180 ... 3910 Ω
  • Installation in Zone 2 zulässig
  • Eingang eigensicher [Ex ia] IIC
  • Galvanische Trennung zwischen Eingang, Ausgang und Hilfsenergie
  • 1 und 2 Kanäle
ATEX / IECEx Classe I (NEC 505) (NEC 506) Classe I Classe II Classe III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Interface Ex i x x x x x x Interface Ex i x x x Interface Ex i x x x x x x
Installation en x*) x*) Installation en x*) x*) Installation en x*) x*) x*)
Resistance Isolator  for Pt 1000 Type 9180/.1
Resistance Isolator for Pt 1000 Type 9180/.1
  • World-wide unique dual channel solution
    • space saving, only 8.8 mm per channel
  • For 2-, 3- and 4-wire circuits
  • Intrinsically safe input [EEx ia] IIC
  • Galvanic isolation between input, output and power supply
  • 1 and 2 channels
  • Installation possible in Zone 2

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

 

X

X

Temperature Transmitter with Output 0/4  ... 20 mA, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.-11
Temperature Transmitter with Output 0/4 ... 20 mA, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.-11
  • One unit for nearly all temperature sensors indivdually configurable
  • Intrinsically safe input [Ex ia] IIC
  • 1 and 2 channels
  • Signal duplication possible
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging (can be switched off)
  • Simple configuration with PC or DIP-switches
  • Installation possible in Zone 2 and Div. 2

 

Zones

0

1

2

20

21

22

Ex i
interfaces

X

X

X

X

X

X

Installation in

X

X

Temperature Transmitter with Output 0/4 ... 20 mA, without Limit Value Contact, SIL 2 (Field Circuit Ex i) Type 9182/10-5.-13
Temperature Transmitter with Output 0/4 ... 20 mA, without Limit Value Contact, SIL 2 (Field Circuit Ex i) Type 9182/10-5.-13
  • One unit for nearly all temperature sensors indivdually configurable
  • Intrinsically safe input [Ex ia] IIC
  • 1 channel
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging
  • Simple configuration with PC
  • Installation possible in Zone 2 and Div. 2
  • Can be used up to SIL 2 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i
interfaces

X

X

X

X

X

X

Installation in

X

X

10648E00

10648E00

Temperature Transmitter without Output 0/4 ... 20 mA, with Limit Value Contact (Field Circuit Ex i) Type 9182/.0-50-12
Temperature Transmitter without Output 0/4 ... 20 mA, with Limit Value Contact (Field Circuit Ex i) Type 9182/.0-50-12
  • One unit for nearly all temperature sensors indivdually configurable
  • Intrinsically safe input [Ex ia] IIC
  • 1 and 2 channels
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging (can be switched off)
  • Simple configuration with PC
  • Installation possible in Zone 2 and Div. 2

 

Zones

0

1

2

20

21

22

Ex i
interfaces

X X X X X X

Installation in

X

X

Transmetteur de température boucle de courant Ex i Série 9182
Transmetteur de température boucle de courant Ex i Série 9182
  • Ein Gerät für nahezu alle Temperaturfühler individuell konfigurierbar
  • Eingang eigensicher [Ex ia] IIC
  • 1 und 2 Kanäle
  • Galvanische Trennung zwischen Eingang, Ausgang, Hilfsenergie und Konfigurationsschnittstelle
  • Drahtbruch- / Kurzschlussüberwachung und Meldung (abschaltbar)
  • Einfache Konfiguration mit PC oder DIP-Schalter
  • Installation in Zone 2 und Div. 2 zulässig
ATEX / IECEx Classe I (NEC 505) (NEC 506) Classe I Classe II Classe III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Interface Ex i x x x x x x Interface Ex i x x x Interface Ex i x x x x x x
Installation en x*) x*) Installation en x*) x*) Installation en x*) x*) x*)
Temperature Transmitter with Output 0/4  ... 20 mA and Limit Value Contact, SIL 2 (Field Circuit Ex i) Type 9182/10-51-14
Temperature Transmitter with Output 0/4 ... 20 mA and Limit Value Contact, SIL 2 (Field Circuit Ex i) Type 9182/10-51-14
  • One unit for nearly all temperature sensors indivdually configurable
  • Intrinsically safe input [Ex ia] IIC
  • 1 channel
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging (can be switched off)
  • Simple configuration with PC
  • Installation possible in Zone 2 and Div. 2
  • Can be used up to SIL 2 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i
interfaces

X

X

X

X

X

X

Installation in

X

X

 

10648E00

10648E00